CGFSW - IRONCLAD, 0152
- MSDS: CGFSW
- Manufacturer: ZEP MFG CO
- Product Name: IRONCLAD, 0152
- National Stock Number: 8010-00N032911
Product Identification
Product ID:IRONCLAD, 0152
MSDS Date:04/07/1995
FSC:8010
NIIN:00N032911
MSDS Number: CGFSW
Responsible Party
US
Emergency Phone: 770-435-4200;800-424-9300(CHEMTREC)
Info Phone: 404-352-1680
Cage: 0990Y
Contractor
Telephone: 404-351-2952/404-432-2873
Cage: 0990Y
Ingredients
LIGROINE; (PETROLEUM SPIRITS)
CAS: 8032-32-4
RTECS: OI6180000
Fraction By Weight: 30-40%
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 25-35%
OSHA PEL N/K
ACGIH TLV: N/K
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 25-35%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
BUTANE
CAS: 106-97-8
RTECS: EJ4200000
Fraction By Weight: 25-35%
OSHA PEL 800 PPM
ACGIH TLV: 800 PPM
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SOLVS IN THIS PROD, WHEN
INHALED/ABSORBED IN HARMFUL QTYS, MAY PRDCE CNS DEPRESS W/HDCH,
NAUS, DIZZ & STUPOR. VAPS/SPRAY MISTS MAY BE IRRIT TO NASAL & RESP
TRACT. PROD MAY BE IRRIT TO SKIN & EY ES RSLTG IN REDNESS,
ITCH/BURNING. INTRODUCTION OF SOLVS, AS IN ASPIR OF VOMITUS FLUID,
MAY PRDCE CHEM (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: PNEUM. CHRONIC: SKIN WHICH IS
REPEATEDLY DEFATTED BY CONT W/THIS PROD MAY BE MORE SUSCEPTIBLE TO
IRRIT, INFECTION/DERM.
Medical Cond Aggravated by Exposure:EXISTING RESPIRATORY AND SKIN
DISEASES MAY BE AGGRAVATED BY EXPOSURE.
First Aid
First Aid:SKIN: WASH CONTAM SKIN THORO W/SOAP/MILD DETERGENT. APPLY
SKIN CREAM W/LANOLIN. GET MED ATTN IF IRRIT PERSISTS. EYES: IMMED
FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MIN, OCCAS LIFTING UPPER &
LOWER LID S. GET MED ATTN AT ONCE. INHAL: MOVE TOFRESH AIR AT ONCE.
IF BRTHG HAS STOPPED, PERFORM ARTF RESP. GET MED ATTN IMMED.
INGEST: DO NOT INDUCE VOMIT. OF VOMIT OCCURS, KEEP HEAD BELOW HIP
(SUP DAT)
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL AND FOAM.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . DIRECT WATER ONTO INTACT CONTAINERS TO PREVENT
BURSTING.
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE.
Accidental Release
Spill Release Procedures:OBSERVE SFTY PREC DURING SPILL CLEAN-UP. LGE
SPILLS ARE UNLIKELY DUE TO PACKAGING. SPILL MAY BE ABSORBED ON
INERT ABSORB MATL (E.G. ZEP-O-ZORB), & PLACED IN SUITABLE CONTR FOR
DISP. WASH AREA THORO W/ DETERGENT SOLN & RINSE WELL W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:FLAMM! STORE & USE AWAY FROM HEAT,
SPKS, OPEN FLAME & ANY SOURCE OF IGNIT. DO NOT STORE AT TEMPS >
120F/IN DIRECT SUNLIGHT.
Other Precautions:DO NOT PUNCTURE/INCIN CONTR. KEEP PROD AWAY FROM SKIN
& EYES. DO NOT BREATHE SPRAY MISTS/VAPS. KEEP OUT OF REACH OF
CHILDREN.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN IN THE UNLIKELY EVENT THAT EXPOSURE LEVELS
EXCEED THE PEL/TLV, USE A NIOSH APPROVED ORGANIC VAPOR RESPIRATOR
(E.G. ZEP 2211).
Ventilation:PROVIDE LOCAL EXHAUST/VENTILATION AS NEEDED TO KEEP
CONCENTRATION OF VAPORS BELOW EXPOSURE LIMITS (PEL/TLV).
Protective Gloves:NITRILE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:CLTHG/SHOES WHICH BECOME CONTAM W/SUBSTANCE
SHOULD BE REMOVED PROMPTLY & NOT REWORN UNTIL THORO CLEANED.
Supplemental Safety and Health
FIRST AID PROC: LEVEL. GET EMER MED ATTN IMMED. WASTE DISP METH:
CONSULT LOC, STATE & FED AGENCIES FOR PROPER DISP METH IN YOUR
AREA. RCRA HAZ WASTE NUMBER: D001.
Chemical Properties
Spec Gravity:0.845
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SLIGHTLY VISCOUS, TAN, OPAQUE LIQUID WITH SOLVENT
ODOR
Percent Volatiles by Volume:80
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, OPEN FLAME, SPARK.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE, AND
OTHER UNIDENTIFIED ORGANIC COMPOUNDS.
Disposal
Waste Disposal Methods:PROD IS CONSUMED IN USE. DO NOT CRUSH,
PUNCTURE/INCIN SPENT CONTRS. LGE NUMBERS OF AEROSOL CONTRS MAY
REQUIRE HNDLG AS HAZ WASTE, BUT IN MOST STATES TOTAL HAZ WASTE QTYS
< 220 LBS/MONTH MAY ALLOW DISP IN CHEM/INDUS WASTE LANDFILL. (SUP
DAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.